FDR-0181 Automatic oxidation stability tester

Automatic oxidation stability of gasoline analyzer is based on national standards gb / t 8018-87 requirements "determination of oxidation stability of gasoline (induction period method)" under the design and manufacture

Features
1, using computer control technology, automatically detect, calculate and control, simple machine operation, precise control, high degree of automation series of advantages.
2, using the most advanced USB interface with a computer connected to the easy to use.
3, using a metal bath, no pollution, no water, the operation is more convenient.
4, the use of sound insulation system design, saving energy and avoiding the risk of burns to the operator.
5, oxygen bomb test assembly with integrated design, not only greatly shortens the oil and gas pipeline pressure test, the pressure detection more accurate, but due to the high sealability manual needle use, we can guarantee the testing process oxygen bomb a good seal, the test accuracy is guaranteed
6, automatic inflatable, air supply device, automatic leak detection function.
7, curve real-time monitoring of temperature and pressure, visual display of the position of the inflection point, accurate determination result.
Technical Parameters
1, the control mode: Notebooks control
2, detection method: automatic inflation, deflation, automatic detection, automatic identification results, print reports
3, the metal bath temperature control point: 100 ℃ ± 1 ℃;
4, oxygen bomb pressure transmitter measuring range: 0 ~ 1600kPa, accuracy ± 0.2 ‰;
5. Thermometer: with a glass mercury thermometer can then be corrected according to Department of degrees;
6, the ambient temperature: ≤30 ℃; Humidity: ≤80%;
7, Power supply: AC220V ± 10%, 50Hz; heating power: 1600W

Announcement from Portal e-B2B.org

New business partner for Portal e-B2B.org

The end

Photos

Message subject:


Message content:

Your signature
Kind regards,
54.224.184.33
International visitors
GB, 27 DE, 3 US, 3 FR, 1 IR, 1 LV, 1 NL, 1 SN, 1 VN, 1
Total unique visits : 39
Countries : 9
Print SMS from smartphones